A review of 30 studies explores AI’s role in Mohs surgery, highlighting its potential, limitations, and value as a decision-support tool under physician oversight.
Article content
A scoping review of 30 studies published between 2020 and 2025 finds artificial intelligence already at work before, during, and after Mohs micrographic surgery — performing best on narrow, rule-based tasks, and failing in predictable ways: oversimplification, hallucinations, and patient materials written above recommended reading levels. The authors' conclusion is measured, and it is the right one: AI belongs in Mohs as decision support under physician oversight, not as a replacement for the people in the room — or in the laboratory.
Artificial intelligence is being explored across dermatology, and Mohs micrographic surgery is no exception. Chatbots answer patient questions, models assist with planning and documentation, and research groups are testing AI against the specialty's most demanding task — reading frozen sections. What has been missing is a map: where, exactly, has AI been studied inside the Mohs workflow, how well did it perform, and where did it fall short?
A scoping review published online in Dermatologic Surgery on November 20, 2026, by Abdelwahab and colleagues, sets out to draw that map. Its value for a Mohs practice is not a single headline result — a scoping review produces none — but an honest inventory of what the evidence currently supports, and what it does not.
What the review did
The authors performed a literature review in accordance with PRISMA-ScR guidelines — the standard reporting framework for scoping reviews — searching PubMed, ScienceDirect, Scopus, Web of Science, and the Cochrane databases for studies published from 2020 to 2025. Studies evaluating AI applications in Mohs micrographic surgery were included. Thirty studies met the inclusion criteria.
A scoping review is not a meta-analysis. It does not pool results into a single number, and it does not rank treatments. It maps a field: how much research exists, where it concentrates, and what patterns and gaps appear across it. That distinction matters for how this paper should be quoted — as a map of the field, not as a verdict on any single AI tool.
What it found: AI across the whole Mohs workflow
The 30 included studies spanned every phase of the Mohs workflow. Preoperative applications were the most studied, followed by intraoperative and postoperative uses, with a further group spanning multiple phases:
Phase of the Mohs workflow:
Preoperative: 13 studies
Intraoperative: 7 studies
Postoperative: 5 studies
Mixed / multiple phases: 5 studies
Total included: 30 studies
Table: Distribution of the 30 included studies by phase of the Mohs workflow. Source: Abdelwahab et al., Dermatologic Surgery, published online November 20, 2026 (DOI: 10.1097/DSS.0000000000005455).
Across those studies, a consistent performance pattern emerged. AI performed best in structured, narrow, rule-based tasks — the kind of work with defined inputs and a checkable output. Performance was highly dependent on how the task was framed: the structure of the prompt and the quality of the input data materially changed the results. Responses were generally accurate — but with two qualifications that matter for patient-facing use. Generated responses often exceeded recommended patient literacy levels, and output varied across models, so the same question put to different systems did not reliably produce the same answer.
Where AI fell short
The review catalogues the limitations that recurred across the literature:
- Oversimplification — answers that flatten a nuanced clinical situation into a generic one.
- Inability to incorporate patient-specific factors — the comorbidities, anatomy, medications, and history that change real decisions.
- Hallucinations and misinformation — confidently stated content that is wrong, and that a non-expert reader cannot easily detect.
- Difficulty demonstrating soft skills — the reassurance, judgment, and communication on which anxious surgical patients depend.
- Reading level — patient-facing text generated above recommended literacy levels, limiting its usefulness for the patients who most need clear explanations.
None of these failures is surprising, and none is a reason to dismiss the technology. Together they describe a tool that performs well inside a narrow frame and degrades exactly where clinical work becomes individual — which is to say, exactly where Mohs practice lives.
Why this matters in the Mohs laboratory
Seven of the mapped studies were intraoperative — the phase that runs through the laboratory. That is where this review touches histotechnology directly, and its pattern holds there with particular force:
- Structured tasks first. The laboratory work most suited to AI assistance is the structured kind — checklists, documentation, tracking, and standardized prompts — not open-ended interpretation.
- Input quality decides output quality. The review's finding that AI performance depends on input quality has a laboratory parallel every technician already knows: a poorly oriented, thick, or artifact-laden frozen section defeats any reader, human or machine. Section quality remains a human craft, and it gates everything downstream.
- Frozen-section reading stays supervised. Nothing in this literature supports independent AI replacement of roles within Mohs surgery. Where AI touches histologic classification, the evidence supports it as an aid alongside the surgeon and the laboratory team — not instead of them.
- Patient materials need a human editor. If a practice uses AI to draft patient instructions or explanations, the literacy finding applies directly: generated text must be checked and rewritten to a reading level patients can actually use.
Read it honestly: the limitations
- It is a map, not a measurement. A scoping review counts and characterizes studies; it does not pool their results. There is no single accuracy figure for "AI in Mohs," and this paper should never be quoted as providing one.
- The literature is young and moving. The review covers 2020–2025. Models, products, and capabilities change faster than journals publish, so parts of the map were already dated when it appeared — in both directions: some tools have improved, and some claims have not survived contact with practice.
- The underlying studies are heterogeneous. Thirty studies across four workflow phases, with different tools, tasks, and outcome measures, cannot support fine-grained comparisons — and the review does not pretend otherwise.
- Accuracy is not the same as safety. The recurrent limitations — hallucination, oversimplification, blindness to patient-specific factors — are safety-relevant in a surgical workflow, which is precisely why the authors recommend continued physician oversight.
What this means in practice
- Adopt AI where the task is narrow, structured, and verifiable — documentation support, standardized patient information (after a literacy check), and workflow organization — and keep a named human responsible for the output.
- Keep interpretation human-led. Margin assessment and frozen-section reading remain the surgeon's and the laboratory's work; AI assistance there belongs in evaluation and supervised pilots, not in unsupervised production use.
- Treat prompts and inputs as part of the protocol. If output quality depends on prompt structure and input quality, then both belong in written procedures, not in individual habit.
- Do not market what the evidence does not say. "AI-assisted" is accurate where a tool genuinely assists; claims that AI reads slides, replaces staff, or improves outcomes go beyond anything this review — or the literature it maps — establishes.
Conclusion
The picture this scoping review draws is neither hype nor dismissal. Thirty studies in five years show AI already present at every phase of Mohs surgery, strongest where the work is structured and rule-based, weakest where the work becomes individual, communicative, and high-stakes. The authors' conclusion deserves to be quoted in full wherever this topic is discussed in a Mohs practice: AI shows potential for integration into Mohs surgery, continued physician oversight is recommended, and the evidence supports it primarily as a decision support tool — rather than an independent replacement for roles within Mohs surgery. For the laboratory, that is not a threat. It is a job description that still belongs to people.
References
1. Primary source: Abdelwahab RM, Colquitt JK, Abdelwahab M, Vidal NY. Emerging Roles of AI and Chatbots Across the Dermatologic Surgery Workflow: A Scoping Review. Dermatologic Surgery. Published online November 20, 2026. DOI: 10.1097/DSS.0000000000005455.